Technical data sheets

Sika Tack – Panel System

SikaTack®-Panel Systemsika2

Panel fastening system for ventilated facades


facade facade facade
facade Description of the system The SikaTack®-Panel material set is an economical adhesive fastening system for panels in ventilated facades, enabling fastening without the use of mechanical anchoring. The system consists of the SikaTack®-Panel elastic adhesive, the SikaTack®-Panel double-sided fastening and spacer tape and auxiliary materials. The SikaTack®-Panel system enables invisible and non-invasive connection of the facade panel to the substrate.
facade Application Invisible, non-invasive panel mounting system for ventilated facades used outdoors and/or indoors: ♦ Commercial and residential buildings ♦ New and existing buildings ♦ Can be used for interior finishing works
facade Properties ♦ Single-component products, ready to use♦ Fast, economical gluing system♦ Uniform stresses on the entire surface of the panels (no point stresses)♦ High durability and resistance to weather conditions♦ Fastening system absorbs movements and vibrations♦ Allows for the introduction of creative solutions in facade design♦ Aesthetic, easy-to-maintain surface finish♦ The system does not contain silicones
facade Tests facade
facade Approvals Test Report ITB Technical Approval No. AT-15-8111/2009: Set of products for fastening facade cladding panels SikaTack® Panel System, Warsaw 2009 Approval of “Deutsche Institut für Bautechnik” Berlin, Reg. No.: Z-10.8-408Note: Panels intended for application must be previously checked and their suitability for façade use must be confirmed.
facade facade facade

SikaTack®-Panel Adhesive

facade Product description SikaTack®-Panel Adhesive
facade Application One-component adhesive for SikaTack®-Panel kit
facade Product data facade
facade Character facade
facade Color Ivory
facade Packaging 310ml cartridges, 12 cartridges per box 600ml ‘sausage’ cartridges, 20 packs per box
facade Storage facade
facade Storage conditions/Shelf life Best used within 9 months from the production date. Store in appropriate conditions, in factory-sealed, undamaged packaging, in dry conditions, at temperatures of +10°C and +25°C. Protect from direct sunlight.
facade Technical data facade
facade Chemical base Single-component polyurethane, cross-linking under the influence of moisture
facade Density 1,18kg/l       DIN 53 479
facade Skinning time 20 min.        (w. +23° C / 50% wilg. wzgl.)
facade Curing speed 4 mm / 24h   (w +23° C / 50% wilg. wzgl.)
facade Operating temperature -40°C do +90°C
facade building material classification B2     DIN 4102, part 1
facade Mechanical properties facade
facade Shear strength ~ 2,0 MPa
facade Tensile strength ~ 2,50 MPa
facade System Information facade
facade Application Terms facade
facade Ambient temperature Minimum +5°C / Maksimum +35°C

SikaTack® – products for preparing panels before installation

facade SikaTack® – products for preparing panels before installation
facade Application Materials for cleaning and adhesion optimization.
facade Product data facade
facade Character Sika® Cleaner-205      SikaTack®-Panel Primer
facade Color Colorless   Black
facade Packaging 1000 ml      1000 ml250 ml
facade Storage Sika® Cleaner-205  SikaTack®-Panel Primer
facade Storage conditions / Shelf life Best used within 12 and 9 months from the production date, respectively. Store in appropriate conditions, in factory-sealed, undamaged packaging, in dry conditions at a temperature of +10°C to +25°C.
facade Technical data Sika® Cleaner-205   SikaTack®-Panel Primer
facade Chemical base Alcohol solution   Pigmented, solvent based activator EP resin
facade Density 0,8kg/l   1 kg/l
facade Flash-point +14°C    -4°C
facade System Information facade
facade Application Terms facade
facade Ambient temperature Minimum +5°C / Maksimum +35°C

SikaTack®-Panel Fixing Tape

facade SikaTack®-Panel Fixing Tape
facade Application Double-sided, self-adhesive, spacer and fixing tape used for initial fixing of the façade panel (until the elastic adhesive has cured). The tape also ensures a uniform 3 mm thickness of the SikaTack®-Panel adhesive joint.
facade Character facade
facade Color Anthracite
facade Packaging 33m roll
facade Storage conditions / Shelf life Best used within 24 months of production date. Store in appropriate conditions, in factory-sealed, undamaged packaging, in dry conditions at temperatures between +10°C and +25°C. Protect from direct sunlight.
facade Technical data facade
facade Chemical base Closed-cell polyethylene foam
facade Density 0,064 kg/l  DIN 51 757
facade Dimensions 3,3 mm (+ 0.2 mm) x 12 mm
facade Operating temperature -40°C do +70°C
facade Mechanical properties facade
facade Shear strength > 150 godzin (1 kg / 25 x 25 mm)    FTM 2
facade Tensile strength MD 25 N / 15 mm, CD 20 N / 15 mm   DIN 53 455
facade Peel strength > 23 N/ 25 mm (180°C – 30 min.) on stainless steel FTM 1
facade Compressive strength Deflection Compressive strength (ISO 844) 10% 22 kPa 25% 47 kPa 50% 120 kPa
facade Shear strength > 150 godzin (1 kg / 25 x 25 mm)   FTM 2
facade Tensile strength MD 25 N / 15 mm, CD 20 N / 15 mm  DIN 53 455
facade Elongation at break MD 250%, CD 150%  DIN 53 455
facade Peel strength > 23 N/ 25 mm (180°C – 30 min.) na stali nierdzewnej FTM 1
facade Limitations The long-term strength is ensured by the SikaTack-Panel adhesive. The mechanical strength of the SikaTack-Panel tape should not be included in the calculation. The SikaTack-Panel tape should be used over the entire length of the panel-to-substrate connection.
facade System Information facade
facade Application Terms facade
facade Ambient temperature Minimum +10°C / Maksimum +35°C

System Information

System structure

Aluminium substrate The substrate must be approved by the relevant inspection institutions (L, T, H shapes or equivalent). The material must contain at least AIMgSi alloy 0.5 F 22 according to DIN 1748-1.Wooden substrate Perpendicular spruce or pine battens, flat, smooth, with a maximum moisture content of < 14% according to DIN 1052. The bonding surface must be clean, free of any coatings and dust. The gaps between the battens must be at least 1 cm.Design and dimensions The dimensions of the perpendicular surface depend on the façade construction. The gaps between the substrate battens and their width depend on the type of panel and the required loads. Each project requires individual solutions and a description of the details. Examplesat-15-8111_2009_sikatack_panel_system_itb_klejenie_poszczególze_elewacje_wentylowane_rys_2 at-15-8111_2009_sikatack_panel_system_itb_rys1_klejenie_poszczególze_elewacje_wentylowaneRequired width of substrate strips for the SikaTack®-Panel fastening system. System structureThe facade panel must be connected along its entire height. Calculation of maximum values ​​due to permissible load:- Adhesive width: 10 mm- Tensile strength: 0.15 MPa- Shear strength: 0.12 MPa (permissible reduction factor S = 1.0) Working jointsIn order to design and dimension the system correctly, and to ensure a proper vertical connection on an aluminium or wooden substrate, all standard building regulations and provisions for façade works must be taken into account. In order to ensure optimum fastening of the façade panels, all vertical aluminium or wooden battens must be uniform, even and parallel. Gaps and joints in the substrate must not be connected by fasteners. Adequate gaps must be maintained between the panels to allow for movement due to thermal expansion of the material. The linear thermal expansion of the panels and the substrate must be taken into account. In order to ensure adequate ventilation of the entire façade system, adequately sized ventilation openings must be included at the top and bottom of the façade. Note: The design solutions must take into account all details and detailed descriptions of the SikaTack-Panel system.

Application details

facade Material consumption Material Application Consumption SikaTack®-Panel Cartridge 310ml Packaging 600ml Triangular adhesive bead 8 x 10 mm ~ 44 ml / m, refers to 7 m / cartridge or 13 m / packaging 600 ml Sika® Cleaner-205 250 ml bottle 1000 ml bottle Width 50 mm ~ 3.5 ml / m, refers to ~ 71m / 250 ml bottle to ~ 285m / 1000 ml bottle SikaTack®-Panel Primer 1000 ml bottle Width 50 mm ~ 8 ml / m, refers to ~ 125m / 1000 ml bottle SikaTack®-Panel Fixing Tape, roll 33m   1 m / m
facade Ground conditions The substrate must be clean and dry, homogeneous, even, free of grease, oil, lubricants, dust, loose particles, remnants of old coatings, cement laitance, etc. and other elements that may reduce adhesion. Standard construction requirements must be observed.
facade Application Terms facade
facade Substrate temperature Within 5 hours after mounting the system, the ambient temperature should not fall below +5°C.
facade Ambient temperature Minimum +5°C / Maksimum +35°C
facade Material temperature The temperature of building materials (panels, subfloor, etc.) must be at least 3°C ​​above the dew point.
facade Substrate humidity The substrate should be dry, wood moisture < 14%
facade Relative air humidity Below 75%

Leave a Reply